TECHNICAL DATA
Replace open pipe Ø (mm) |
4 |
Blowing force (N) |
3.2 |
Air consumption (Nm³/h) |
19 |
Sound level (dB(A)) |
79 |
Nozzle technology |
Slot |
Material (nozzle) |
Zn |
Connection |
G 1/8" |
Connection type |
Male |
Weight (kg) |
0.0050 |
Max temp (°C) |
70 |
Max op. pressure (MPa) |
1.0 |
Benefits when replacing an open pipe
Replace open pipe Ø (mm) |
4 |
|
Noise reduction |
16 [dB(A)] |
67% |
Energy savings |
11 [Nm³/h] |
37% |
Material specification: EN 1.4305, Zn ZL0410 EN1774
Blowing properties at different pressures
Pressure (kPa) | 200 | 400 | 600 | 800 | 1000 |
Blowing force (N) |
1.4 |
2.6 |
4.0 |
5.1 |
6.3 |
Air consumption (Nm³/h) |
9.3 |
15.3 |
22.8 |
29.8 |
36.8 |
Sound level (dB(A)) |
71.0 |
76.8 |
81.0 |
84.9 |
87.5 |
Blowing coverage
Blowing dist. (mm) | Blowing coverage (mm) |
50 |
24 |
100 |
38 |
200 |
80 |
300 |
114 |
400 |
156 |
500 |
194 |